Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Echocardiography ; 39(7): 906-917, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35733298

RESUMO

BACKGROUND: Transesophageal echocardiography (TEE) is the gold standard for the detection of valvular vegetations (VV). Differentiating small VV from degenerative changes is challenging and prone to inter-observer variability. We evaluated inter-observer agreement regarding aortic (AV) and mitral valve (MV) findings on TEEs ordered for suspected infective endocarditis (IE). METHODS: A total of 349 consecutive TEEs were evaluated. Studies were classified as "definite, possible, or no" IE with valve masses classified further by morphology. Nine faculty echocardiographers scored randomly selected TEEs of the AV (N = 38) and MV (N = 35). Inter-reader variability was calculated using the Fleiss/Scott Kappa (Kf). RESULTS: Positive blood cultures were present in 81% and 45% had definite IE by the modified Duke criteria. There was moderate reader agreement regarding the presence of a valvular mass for both the AV (Kf = .41, 95% CI [.30-.53]) and MV (Kf = .49, 95% CI [.34-.65]). For diagnosis of IE, there was fair agreement for the AV (Kf = .29, 95% CI [.18-.42]) and moderate agreement for the MV (Kf = .53, 95% CI [.36-.70]). Masses described as large, multi-lobulated, or pedunculated were more frequently categorized as clinical IE, (p < .006, both valves), however those with filamentous lesions were not (p < .001, both valves). CONCLUSIONS: In a large academic center, the inter-observer agreement for the presence of a left sided valvular mass was moderate and agreement regarding the final diagnosis of IE was fair to moderate, with better agreement among readers evaluating the MV. Lesion morphology is associated with the clinical diagnosis of IE.


Assuntos
Endocardite Bacteriana , Endocardite , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Ecocardiografia Transesofagiana , Endocardite/complicações , Endocardite/diagnóstico por imagem , Endocardite Bacteriana/complicações , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/patologia , Variações Dependentes do Observador
3.
Med Phys ; 48(5): 2528-2542, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33608930

RESUMO

PURPOSE: Several types of structural heart intervention (SHI) use information from multiple imaging modalities to complete an interventional task. For example, in transcatheter aortic valve replacement (TAVR), placement and deployment of a bioprosthetic aortic valve in the aorta is primarily guided by x-ray fluoroscopy (XRF), and echocardiography provides visualization of cardiac anatomy and blood flow. However, simultaneous interpretation of independent x-ray and echo displays remains a challenge for the interventionalist. The purpose of this work was to develop a novel echo/x-ray co-registration solution in which volumetric transthoracic echo (TTE) is transformed to the x-ray coordinate system by tracking the three-dimensional (3D) pose of a probe fiducial attachment from its appearance in two-dimensional (2D) x-ray images. METHODS: A fiducial attachment for a commercial TTE probe consisting of rings of high-contrast ball bearings was designed and fabricated. The 3D pose (position and orientation) of the fiducial attachment is estimated from a 2D x-ray image using an algorithm in which a virtual point cloud model of the attachment is iteratively rotated, translated, and forward-projected onto the image until the average sum-of-squares of grayscale values at the projected points is minimized. Fiducial registration error (FRE) and target registration error (TRE) of this approach were evaluated in phantom studies using TAVR-relevant gantry orientations and four standard acoustic windows for the TTE probe. A patient study was conducted to assess the clinical suitability of the fiducial attachment prototype during TTE imaging of patients undergoing SHI. TTE image quality for the task of guiding a transcatheter procedure was evaluated in a reviewer study. RESULTS: The 3D FRE ranged from 0.32 ± 0.03 mm (mean ± SD) to 1.31 ± 0.05 mm, depending on C-arm orientation and probe acoustic window. The 3D TRE ranged from 1.06 ± 0.03 mm to 2.42 ± 0.06 mm. Fiducial pose estimation was stable when >75% of the fiducial markers were visible in the x-ray image. A panel of reviewers graded the presentation of heart valves in TTE images from 48 SHI patients. While valve presentation did not differ significantly between acoustic windows (P > 0.05), the mitral valve did achieve a significantly higher image quality compared to the aortic and tricuspid valves (P < 0.001). Overall, reviewers perceived sufficient image quality in 76.5% of images of the mitral valve, 54.9% of images of the aortic valve, and 48.6% of images of the tricuspid valve. CONCLUSIONS: Fiducial-based tracking of a commercial TTE probe is compatible with clinical SHI workflows and yields 3D target registration error of less than 2.5 mm for a variety of x-ray gantry geometries and echo probe acoustic windows. Although TTE image quality with respect to target valve anatomy was sufficient for the majority of cases examined, prescreening of patients for sufficient TTE quality would be helpful.


Assuntos
Valva Aórtica , Marcadores Fiduciais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fluoroscopia , Humanos , Imageamento Tridimensional , Imagens de Fantasmas , Reprodutibilidade dos Testes , Raios X
4.
Am J Cardiol ; 123(1): 169-174, 2019 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-30348435

RESUMO

Sudden cardiac death in a young healthy athlete is a rare but catastrophic event. The American Heart Association preparticipation screening guidelines recommend a focused history and physical without routine imaging or electrocardiogram screening. We hypothesized that a focused echocardiogram can identify structural abnormalities that may lead to sudden cardiac death in athletes, which might otherwise go undetected by history and physical. We retrospectively reviewed the charts of all incoming collegiate athletes at a single university from 2005 to 2013, all of whom had undergone a focused, 5-minute echocardiogram along with a guideline-based preparticipation history and physical (PPS H&P). Abnormal findings prompted further testing or referral. We report the prevalence of abnormal findings and the relation between an abnormal PPS H&P and screening echocardiogram. A total of 2,898 athletes were screened and 159 (5%) had findings. Forty athletes underwent further testing and evaluation. Of these athletes, 3 had newly diagnosed abnormalities that warranted restriction of participation: 1 apical-variant hypertrophic cardiomyopathy, 1 large bidirectional atrial septal defect with right ventricular dysfunction, and 1 dilated ascending aorta. Two of these athletes had a normal PPS H&P. Conversely, of the 661 athletes with an abnormal PPS H&P, only 1 (0.15%) had an abnormal screening echocardiogram. In conclusion, although the overall number was low, the 5-minute screening echocardiogram detected athletes at risk for sudden cardiac death not discovered on PPS H&P.


Assuntos
Atletas , Morte Súbita Cardíaca/prevenção & controle , Ecocardiografia/métodos , Programas de Rastreamento/métodos , Estudantes , Adolescente , Adulto , Feminino , Humanos , Masculino , Estudos Retrospectivos , Estados Unidos , Universidades , Wisconsin
7.
Am J Cardiol ; 118(12): 1831-1835, 2016 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-28029361

RESUMO

Patients with newly diagnosed atrial fibrillation (AF) and a rapid ventricular response may present with a reduced left ventricular ejection fraction (LVEF). We compared long-term outcomes of these patients with those with preserved LVEF. This retrospective cohort study included 385 consecutive adults with newly diagnosed AF with rapid ventricular response, presenting to a single medical center from January 2006 to August 2014. Patients with a history of coronary artery disease or known cardiomyopathy were excluded. Patients were divided into 2 groups: those with an LVEF ≤55% (n = 147) (REF) and those with an LVEF >55% (n = 238) (PEF). Echocardiographic parameters, all-cause mortality, cardiovascular mortality, and stroke rates were compared between both groups at baseline and a minimum of 1-year follow-up. The mean age of patients was 68 ± 1.1 in REF versus 60 ± 7.4 in PEF (p = 0.39). There were no significant differences in baseline co-morbidities between both groups. The mean LVEF during the index admission was 47.7 ± 0.8% in REF versus 65.5 ± 0.3% in PEF. The average duration of follow-up was 2.8 years. Patients with REF had higher all-cause mortality (32.7% REF vs 20.6% PEF, odds ratio 2.17, p = 0.008). Patients with REF had higher rates of subsequent clinic or ER visits for AF with a rapid ventricular response (32% REF vs 22.7% PEF, p = 0.044). The incidence of stroke was similar between both groups (17% REF vs 18.9% PEF, p = 0.639). Of the patients with REF, 64% had subsequent EF recovery and had similar outcomes compared with patients with PEF. Baseline LV end-diastolic diameter predicted all-cause mortality (odds ratio 1.14, p = 0.003) in the REF group. None of the echocardiographic parameters predicted EF recovery. In conclusion, in patients with new AF with rapid ventricular response, REF was associated with higher long-term all-cause mortality. Those with subsequent LVEF recovery after medical therapy appear to have a similar prognosis compared with those with initial PEF.


Assuntos
Fibrilação Atrial/fisiopatologia , Volume Sistólico , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Doenças Cardiovasculares/mortalidade , Estudos de Coortes , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mortalidade , Razão de Chances , Prognóstico , Estudos Retrospectivos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia
8.
J Am Heart Assoc ; 4(10): e002254, 2015 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-26508741

RESUMO

BACKGROUND: Familial hypercholesterolemia (FH) is a prevalent hereditary disease associated with increased atherosclerosis and calcific aortic valve disease (CAVD). However, in both FH and non-FH individuals, the role of hypercholesterolemia in the development of CAVD is poorly understood. This study used Rapacz FH (RFH) swine, an established model of human FH, to investigate the role of hypercholesterolemia alone in the initiation and progression of CAVD. The valves of RFH swine have not previously been examined. METHODS AND RESULTS: Aortic valve leaflets were isolated from wild-type (0.25- and 1-year-old) and RFH (0.25-, 1-, 2-, and 3-year-old) swine. Adult RFH animals exhibited numerous hallmarks of early CAVD. Significant leaflet thickening was found in adult RFH swine, accompanied by extensive extracellular matrix remodeling, including proteoglycan enrichment, collagen disorganization, and elastin fragmentation. Increased lipid oxidation and infiltration of macrophages were also evident in adult RFH swine. Intracardiac echocardiography revealed mild aortic valve sclerosis in some of the adult RFH animals, but unimpaired valve function. Microarray analysis of valves from adult versus juvenile RFH animals revealed significant upregulation of inflammation-related genes, as well as several commonalities with atherosclerosis and overlap with human CAVD. CONCLUSIONS: Adult RFH swine exhibited several hallmarks of early human CAVD, suggesting potential for these animals to help elucidate CAVD etiology in both FH and non-FH individuals. The development of advanced atherosclerotic lesions, but only early-stage CAVD, in RFH swine supports the hypothesis of an initial shared disease process, with additional stimulation necessary for further progression of CAVD.


Assuntos
Valva Aórtica/patologia , Calcinose/etiologia , Doenças das Valvas Cardíacas/etiologia , Hiperlipoproteinemia Tipo II/complicações , Fatores Etários , Animais , Valva Aórtica/metabolismo , Valva Aórtica/fisiopatologia , Biomarcadores/metabolismo , Calcinose/genética , Calcinose/metabolismo , Calcinose/patologia , Calcinose/fisiopatologia , Colesterol/sangue , Modelos Animais de Doenças , Progressão da Doença , Matriz Extracelular/metabolismo , Feminino , Regulação da Expressão Gênica , Doenças das Valvas Cardíacas/genética , Doenças das Valvas Cardíacas/metabolismo , Doenças das Valvas Cardíacas/patologia , Doenças das Valvas Cardíacas/fisiopatologia , Hiperlipoproteinemia Tipo II/genética , Hiperlipoproteinemia Tipo II/metabolismo , Macrófagos/metabolismo , Macrófagos/patologia , Oxirredução , Placa Aterosclerótica , Suínos , Fatores de Tempo
10.
J Emerg Med ; 45(6): 947-57, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23937807

RESUMO

BACKGROUND: Patients with possible acute coronary syndrome (ACS) are typically instructed to return to the emergency department (ED) if their condition worsens. Little is known about the relationship between patient satisfaction in the ED and subsequent return visits. OBJECTIVE: Our aim was to determine the association between satisfaction with ED care and subsequent ED return visits. METHODS: One thousand and five consecutive ED patients with symptoms of possible ACS who participated in a prospective guideline implementation trial at two university hospitals completed a telephone survey at 30-day follow-up. Satisfaction with care at the initial ED visit was measured using items from the Press Ganey satisfaction questionnaire. Logistic regression was used to determine the association between individual satisfaction items and the occurrence of any ED revisits, and the association between satisfaction items and return visits to the same ED. RESULTS: Patients who reported superior ratings of person-centered care ("staff cared about you as a person") were significantly less likely to return to any ED during 30-day follow-up: 59 vs. 71%, adjusted odds ratio = 0.57 (95% confidence interval 0.37-0.87). Among those with ED revisits, superior ratings of personal care and perceived waiting time for emergency physician evaluation were significantly associated with return to the same ED. CONCLUSIONS: Although diagnostic workup and risk stratification are the primary focus in evaluating patients with possible ACS, greater attention to the patient's experience of care may have the positive impact of reducing ED return visits and increasing the likelihood that patients will return to the same ED for re-evaluation.


Assuntos
Síndrome Coronariana Aguda/terapia , Serviço Hospitalar de Emergência/normas , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Readmissão do Paciente/normas , Satisfação do Paciente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Assistência Centrada no Paciente/normas , Inquéritos e Questionários , Wisconsin
12.
Echocardiography ; 30(9): 1022-31, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23551740

RESUMO

Guidelines for assessing diastolic function by echocardiography are continually being updated. Our ability to use available guidelines effectively has not been completely investigated. Six trained echocardiographers were asked to interpret 105 echocardiograms using current American Society of Echocardiography (ASE) algorithms for interpretation of diastolic grade and estimation of left atrial (LA) pressure. Diastolic grade was categorized as normal, mild, moderate, or severe dysfunction. The presence or absence of elevated LA pressure was determined using a second ASE algorithm. As a reference comparison for level of agreement, left ventricular ejection fraction was visually determined. By the ASE algorithm, 29 subjects (28%) met all measurement criteria in their assigned grade and 57 subjects (55%) met all or all but one criterion of their assigned grade. Of the 45 subjects (43%) for whom the guidelines disagreed by more than 1 criterion, the readers debated between normal and moderate dysfunction in 22% or mild and moderate diastolic dysfunction in 31%. Percent inter-reader agreement and kappa values were 76% (0.7) for determining diastolic grade, 84% (0.67) for determining elevated LA pressure, and 84% (0.67) for estimation of ejection fraction, the reference standard. For all subjects, if multiple echocardiographic criteria failed to fit into the proposed guidelines, agreement fell to 66% (0.58) for determining diastolic grade and 74% (0.48) for determining LA pressure. There is reasonable agreement estimating diastolic grade and LA pressure using current guidelines. Further refinements in the definition of mild and moderate dysfunction may improve agreement.


Assuntos
Ecocardiografia/normas , Fidelidade a Diretrizes/estatística & dados numéricos , Interpretação de Imagem Assistida por Computador/métodos , Interpretação de Imagem Assistida por Computador/normas , Guias de Prática Clínica como Assunto , Disfunção Ventricular Esquerda/diagnóstico por imagem , Idoso , Feminino , Humanos , Aumento da Imagem/métodos , Aumento da Imagem/normas , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Prevalência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estados Unidos/epidemiologia , Disfunção Ventricular Esquerda/classificação
13.
Echocardiography ; 30(5): 513-20, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23311405

RESUMO

BACKGROUND: The HeartMate II is the most frequently used left ventricular assist device (LVAD) in patients with end-stage heart failure. There is a paucity of data regarding its longitudinal cardiac effects, particularly that on diastole. METHODS: This retrospective study was an evaluation of echocardiograms preoperatively and at 3, 6, and 12 months postoperatively in patients with a HeartMate II. Measurements included left ventricle (LV) dimensions, ejection fraction (EF), right ventricle (RV) size and function, parameters of diastolic function, and an analysis of mitral regurgitation (MR), tricuspid regurgitation (TR), aortic insufficiency (AI), and aortic valve thickening. RESULTS: Forty-seven patients were evaluated. LV dimensions decreased but EF, RV size, and RV function were unchanged. Right ventricular systolic pressure (RVSP) and diastolic parameters including mitral inflow E/A, deceleration time (DT), pulmonary vein inflow, left atrial size, and overall diastolic grade improved. LV relaxation measured by tissue Doppler (e') was unchanged and the E/e' ratio was also unchanged. Regarding valve function, MR decreased, TR was unchanged, and the aortic valve became increasingly thickened with increased AI severity. CONCLUSIONS: The HeartMate II unloads the LV as shown by decreased LV size, decreased MR, reduced RVSP, and improved patterns of mitral inflow. However, neither systolic function nor diastolic relaxation improves in this cohort. RV size and function also remain unchanged. The aortic valve shows increased thickening and AI likely from valve leaflet fusion. These results provide detailed functional and hemodynamic information regarding the longitudinal effects of the HeartMate II.


Assuntos
Ecocardiografia Doppler/métodos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Hemodinâmica/fisiologia , Adulto , Estudos de Coortes , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Testes de Função Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Cuidados Pós-Operatórios , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/fisiopatologia , Cuidados Pré-Operatórios , Estudos Retrospectivos , Medição de Risco , Volume Sistólico , Taxa de Sobrevida , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia , Função Ventricular Direita/fisiologia
14.
Artigo em Inglês | MEDLINE | ID: mdl-22254302

RESUMO

The TASER® Conducted Electrical Weapon (CEW) is used by law enforcement agencies about 900 times per day worldwide and has been shown to reduce suspect and officer injuries by about 65%. However, since a CEW delivers rapid electrical pulses through injected probes, the risk of inducing ventricular fibrillation (VF) has been considered. Animal studies have shown that the tip of the probe must come within a few millimeters of the surface of the heart for the CEW to induce VF in a typical animal application. Early calculations of the CEW VF risk in humans used sophisticated 3-D chest models to determine the size of the probe landing areas that had cardiac tissue within a given distance of the inner surface of the ribs. This produced a distribution of area (cm(2)) vs. mm of depth. Echocardiography was then used to determine the shortest distance from the skin surface to the cardiac surface. This produced a population distribution of skin-to-heart (STH) distances. These 2 distributions were then convolved to arrive at a probability of inducing VF for a typical human CEW application. With 900, 000 probe-mode field uses to date, epidemiological results have shown that these initial VF risk estimates were significant overestimates. We present model refinements that take into account the gender and body-mass-index (BMI) of the target demographics and produce VF risk estimates concordant with the epidemiological results. The risk of VF is estimated at 0.4 per million uses with males.


Assuntos
Lesões por Armas de Eletrochoque/epidemiologia , Lesões por Armas de Eletrochoque/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Modelos Cardiovasculares , Modelos de Riscos Proporcionais , Fibrilação Ventricular/epidemiologia , Animais , Comorbidade , Lesões por Armas de Eletrochoque/prevenção & controle , Humanos , Prevalência , Medição de Risco/métodos , Fatores de Risco , Fibrilação Ventricular/fisiopatologia
15.
Curr Cardiol Rep ; 12(3): 243-9, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20424968

RESUMO

Three-dimensional echocardiography is a growing imaging modality, particularly for the evaluation of mitral valve pathology. Functional anatomy in disease states such as mitral regurgitation and stenosis as well as prosthetic valves can be effectively studied, offering superior knowledge to treating physicians. Additionally, three-dimensional echocardiography has the ability to help guide operative and percutaneous interventions, allowing for improved patient outcomes and advancement of clinical research. Continued experience with three-dimensional echocardiography will further our knowledge of the mitral valve and refine current indications for cardiovascular imaging.


Assuntos
Ecocardiografia Tridimensional , Insuficiência da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca , Humanos , Valva Mitral/patologia , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/patologia , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/patologia , Prolapso da Valva Mitral/cirurgia , Estenose da Valva Mitral/patologia , Estenose da Valva Mitral/cirurgia
17.
Congest Heart Fail ; 15(2): 58-62, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19385118

RESUMO

Predictors of myocardial recovery after ventricular assist device (VAD) implantation are not well defined. The authors report their current VAD weaning protocol. Between 2003 and 2006, 38 patients received VAD implants. The authors performed 5 tests in 4 patients in whom echocardiography findings suggested myocardial recovery after implant. The protocol consists of assessing symptoms, electrocardiographic findings, hemodynamics, and cardiac function at baseline and as VAD support is weaned. As a result, 3 patients passed the weaning protocol and were explanted. There has been no recurrence of heart failure 667, 752, and 1007 days after explant, respectively. One patient failed the protocol after 151 days of support because of low cardiac index during the protocol. This patient was transplanted. This current experience of VAD weaning protocol is a novel tool to identify candidates for successful VAD explantation.


Assuntos
Remoção de Dispositivo , Insuficiência Cardíaca/reabilitação , Coração Auxiliar , Recuperação de Função Fisiológica/fisiologia , Disfunção Ventricular Esquerda/reabilitação , Adulto , Cardiotônicos/administração & dosagem , Dobutamina/administração & dosagem , Ecocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Hemodinâmica/efeitos dos fármacos , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Milrinona/administração & dosagem , Contração Miocárdica/fisiologia , Recuperação de Função Fisiológica/efeitos dos fármacos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...